I/O Config Menu / 5.2 - Relay Remap
MiniHPC has five relay outputs (R1 - R5), to which individual functions are assigned by default. These functions can be modified and exchanged according to the user's needs.
- the switching logic can be inverted for each of the outputs (e.g., in case the direction of water flow through the 3-way valve is reversed).Functions available for assignment:
- DHW - DHW electric heater (R1)
- ELH - central heating heater (R2)
- PMP - circulation pump (R3)
- 3VD - 3-way valve for DHW (R4)
- 3VC - 3-way cooling valve (R5)
- OHC - outdoor unit heating cable in 8.5 ODU heating cable
- DCP - DHW circulation pump in 3.8 DHW circulation pump
If necessary, a single function can also be set for multiple relay outputs. For example, when connecting an SPDT 3-way valve, the function can be assigned to two outputs, one of which will be inverted, and the 3-way valve will use both of these outputs for its switching.