Menu I/O config / 5.3 - Input switch Functions

The 5.3 - Input Functions menu in the service menu is used to assign inputs S1 and S2 to specific MiniHPC device control functions. For each input, you can set the function, offset (shift value), and global parameters for the minimum on and off time.

Usage note (Smart Grid / PV): This function works similarly to Smart Grid systems. Using external signals (e.g., from a photovoltaic inverter during energy surplus or from an ripple control signal), the device can dynamically change the required temperatures or power limits, effectively utilizing cheap or eco-friendly energy for heating, cooling, or DHW heating.
Input Parameters
- Input: Selection of the assigned input (e.g., S1, S2, S1i, S2i or disabled). S1i and S2i are inputs with inverted logic, meaning they trigger the function when the inputs are turned off.
- Function: Determines what the given input affects. The following options are available:
- Off: The input is inactive.
- T1 (Room temperature): Affects the target temperature according to the room sensor.
- T2/T3 (Heating): Water temperature correction for heating.
- T3 (Cooling): Water temperature correction for cooling.
- T3eqtr: Heating curve offset.
- DHW: Required domestic hot water temperature.
- Power limit: Limiting the maximum power consumption from menu 7.4 input power.
- Offset: Shift value or target quantity assigned to the given function, whose range and units depend on the selected function.
Note: A single input can control multiple functions, and conversely, a single function can be assigned to multiple inputs. In this case, and when both inputs are activated with the same function, the set offsets are added together.
Minimum Times
Setting these times prevents short switching on or off of the inputs, thus solving potential function cycling issues. A typical example is connecting the input to the output of a photovoltaic regulator, which could turn the input on or off within a short time frame due to variable cloud cover.
- Min. ON time: The minimum duration for which the state must be active.
- Min. OFF time: The minimum period of inactivity between two switch-ons.