DHW Menu / 3.8 - DHW circulation pump
The circulation pump for DHW can be controlled by a simple plug-in timer or left to be triggered by MiniHPC.
To control the pump, you can adjust 2 time intervals (e.g. morning and evening), adjust cycle switching and pause times between pump activations, and a function for sterilizing the circulation circuit is also available. This means that the circulation pump will switch on for a set duration whenever the water heater is heated to a high temperature by function 3.3 Anti-legionella. This ensures flushing the piping with hot water.
To activate this function, it is necessary to assign the DCP function to the selected Relay output in menu 5.2 Relay remap.
A quick shortcut to the relay remapping menu is available by pressing the button at the top of this menu.